beautypg.com

Dell PowerEdge SC1435 User Manual

Page 21

background image

About Your System

21

Time-of-day not set -

please run SETUP program

Incorrect Time or Date settings;
faulty system battery.

Check the Time and Date settings. See
"Using the System Setup Program" on
page 23. If the problem persists,
replace the system battery. See "System
Battery" on page 59.

Timer chip counter 2

failed

Faulty system board.

See "Getting Help" on page 95.

Unsupported CPU

combination

Unsupported CPU stepping

detected

Microprocessor(s) is not supported
by the system.

Install a supported microprocessor or
microprocessor combination. See
"Processors" on page 50.

Utility partition not

available

The key was pressed during
POST, but no utility partition exists
on the boot hard drive.

Create a utility partition on the boot
hard drive. See the CDs that came
with your system.

Warning: DIMM

n

and

n

are

faulty and disabled.

Total memory size is

reduced!

Faulty or improperly seated memory
module(s).

See "Troubleshooting System Memory"
on page 76.

Warning! No microcode

update loaded for

processor

n

Microcode update failed.

Update the BIOS firmware. See
"Getting Help" on page 95.

Warning: One or more

faulty DIMMs found on

CPU

n

Faulty or improperly seated memory
module(s) used by CPU

n.

See "Troubleshooting System Memory"
on page 76.

Warning: The installed

memory configuration is

not optimal. For more

information on valid

memory configurations,

please see the system

documentation on the

technical support web

site.

Invalid memory configuration. The
system will run but with reduced
functionality.

Ensure that the memory modules are
installed in a valid configuration. See
"Memory Module Installation
Guidelines" on page 46. If the problem
persists, see "Troubleshooting System
Memory" on page 76.

Write fault

Write fault on selected

drive

Faulty diskette, optical/diskette
drive assembly, hard drive, or hard-
drive subsystem.

See "Troubleshooting a USB Device"
on page 71, "T
roubleshooting an
Optical Drive" on page 78, or
"Troubleshooting a Hard Drive" on
page 78.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 121.

Table 1-6.

System Messages (continued)

Message

Causes

Corrective Actions