Enabling and disabling failback on an n_port, Figure 11, Failback – Dell POWEREDGE M1000E User Manual
Page 69
Access Gateway Administrator’s Guide
49
53-1001760-01
Failback
3
FIGURE 11
Failback behavior
Enabling and disabling Failback on an N_Port
Use the following steps to enable or disable Failback on N_Ports.
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the ag
--
failbackshow n_portnumber command to display the failover setting.
switch:admin> ag --failbackshow 13
Failback on N_Port 13 is not supported
3. Use the following commands to enable or disable Failback:
•
Enter the ag
--
failbackenable n_portnumber command to enable failback.
switch:admin> ag --failbackenable 13
Failback policy is enabled for port 13
•
Enter the ag --failbackdisable n_portnumber command to disable failback.
switch:admin> ag --failbackdisable 13
Failback policy is disabled for port 13