Dell PowerVault 124T User Manual
Page 50
E9
Time Update Event
The system time was changed. No action required.
Front Panel Error Types
EA
LCD Busy Error
Possible LCD controller problem, software error, or communication error.
l
Power cycle the autoloader.
l
Run the Random Moves test.
l
EB
LCD Goto Error
EC
Login/Password Error
Incorrect login from front panel.
l
Use correct login/password.
ED
Socket Error During SNTP
Barcode Error Types
F0
Bar Code Init Error
l
Remove magazines and inspect cartridges. Verify that valid barcode labels are being used on all
cartridges, and re-insert the magazines.
l
If barcode labels are not being used, disable the barcode reader through the Operator Control Panel
or Remote Management Unit.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
l
F1
Bar Code Hardware Error
F2
Bar Code Baud Rate Error
F3
Bar Code Handshake Error
F4
Bad/Noisy Response From Bar
Code Reader
F5
Checksum Failed
Incomplete barcode label or barcode checksum failed.
l
Repeat test with new cartridge or label.
l
If problems recur with the original cartridge or label, replace.
l
F6
Barcode No Read
Barcode label not present.
l
Apply valid barcode label to cartridge, or disable the barcode reader through the Operator Control
Panel or Remote Management Unit.
F7
Barcode Mismatch Error
l
Power cycle the autoloader.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
l
F8
Barcode Duplicate Label Error
Duplicate barcode.
Diagnostic Error Types
F9
Diagnostic Test Failure
l
Power cycle the autoloader.
l
Re-run the failing diagnostic test.
l
FA
Diagnostic Error, Drive
Reporting Write Protect
l
Verify that valid, not data protected media is present for test.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
l
FB
Diagnostic Error, Cleaning Tape
Inserted
FC
Diagnostic Load Tape Prompt
This is a prompt to manually load a cartridge as required for test.
FD
Diagnostic Unknown Tape
Format
l
Verify that valid, not data protected media is present for test.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
l
FE
Diagnostic Invalid Configuration This is an indication that a minimum of two pieces of media are required for test.
l
Insure at least two cartridges are present in the autoloader and re-run the failed test.