Table 18 — Complete C Control Current LED

Status and Alarm Relay Operations

LEGEND

NOTES:
1. Slow flash is 1 flash every 2 seconds.
2. Fast flash is 2 flashes every 1 second.
3. EXAMPLE: “Flashing Code 2” is represented by 2 fast flashes followed by a

10-second pause. This sequence will repeat continually until the fault is
cleared.

Table 19 — Complete C Control LED Code and

Fault Descriptions

LEGEND

Table 20 — Aquazone™ Deluxe D Control Current LED Status and Alarm Relay Operations

LEGEND

NOTES:
1. If there is no fault in memory, the Fault LED will flash code 1.
2. Codes will be displayed with a 10-second Fault LED pause.
3. Slow flash is 1 flash every 2 seconds.
4. Fast flash is 2 flashes every 1 second.
5. EXAMPLE: “Flashing Code 2” is represented by 2 fast flashes fol-

lowed by a 10-second pause. This sequence will repeat continually
until the fault is cleared.

LED STATUS

DESCRIPTION OF OPERATION

ALARM RELAY

On

Normal Mode

Open

Normal Mode with

PM Warning

Cycle

(closed 5 sec.,

Open 25 sec.)

Off

Control is non-functional

Open

Slow Flash

Fault Retry

Open

Fast Flash

Lockout

Closed

Slow Flash

Over/Under Voltage Shutdown

Open

(Closed after

15 minutes)

Flashing Code 1

Test Mode — No fault in memory

Cycling Code 1

Flashing Code 2

Test Mode — HP Fault in memory

Cycling Code 2

Flashing Code 3

Test Mode — LP Fault in memory

Cycling Code 3

Flashing Code 4 Test Mode — FP1 Fault in memory

Cycling Code 4

Flashing Code 5 Test Mode — FP2 Fault in memory

Cycling Code 5

Flashing Code 6

Test Mode — CO Fault in memory

Cycling Code 6

Flashing Code 7

Test Mode — Over/Under

shutdown in memory

Cycling Code 7

Flashing Code 8

Test Mode — PM in memory

Cycling Code 8

Flashing Code 9

Test Mode — Test Mode — FP1/

FP2 Swapped Fault in memory

Cycling Code 9

CO

Condensate Overflow

FP

Freeze Protection

HP

High Pressure

LED — Light-Emitting Diode
LP

Low Pressure

PM

Performance Monitor

LED

CODE

FAULT

DESCRIPTION

1

No fault in memory

There has been no fault since
the last power-down to power-up
sequence

2

High-Pressure Switch

HP Open Instantly

3

Low-Pressure Switch

LP open for 30 continuous sec-
onds before or during a call
(bypassed for first 60 seconds)

4

Freeze Protection Coax
— FP1

FP1 below Temp limit for 30 con-
tinuous seconds (bypassed for
first 60 seconds of operation)

5

Freeze Protection Air Coil
— FP2

FP2 below Temp limit for 30 con-
tinuous seconds (bypassed for
first 60 seconds of operation)

6

Condensate overflow

Sense overflow (grounded) for
30 continuous seconds

7

(Autoreset)

Over/Under Voltage
Shutdown

"R" power supply is <19VAC or
>30VAC

8

PM Warning

Performance Monitor Warning
has occurred.

9

FP1 and FP2 Thermistors
are Swapped

FP1 temperature is higher than
FP2 in heating/test mode, or FP2
temperature is higher than FP1
in cooling/test mode.

FP

Freeze Protection

HP

High Pressure

LED — Light-Emitting Diode
LP

Low Pressure

PM

Performance Monitor

DESCRIPTION

STATUS LED

(Green)

TEST LED

(Yellow)

FAULT LED (Red)

ALARM RELAY

Normal Mode

On

Off

Flash Last Fault Code in Memory

Open

Normal Mode with PM

On

Off

Flashing Code 8

Cycle (closed 5 sec,

open 25 sec, …)

Deluxe D Control is

non-functional

Off

Off

Off

Open

Test Mode

On

Flash Last Fault Code in Memory

Cycling Appropriate Code

Night Setback

Flashing Code 2

Flash Last Fault Code in Memory

ESD

Flashing Code 3

Flash Last Fault Code in Memory

Invalid T-stat Inputs

Flashing Code 4

Flash Last Fault Code in Memory

No Fault in Memory

On

Off

Flashing Code 1

Open

HP Fault

Slow Flash

Off

Flashing Code 2

Open

LP Fault

Slow Flash

Off

Flashing Code 3

Open

FP1 Fault

Slow Flash

Off

Flashing Code 4

Open

FP2 Fault

Slow Flash

Off

Flashing Code 5

Open

CO Fault

Slow Flash

Off

Flashing Code 6

Open

Over/Under Voltage

Slow Flash

Off

Flashing Code 7

Open (closed after 15 minutes)

HP Lockout

Fast Flash

Off

Flashing Code 2

Closed

LP Lockout

Fast Flash

Off

Flashing Code 3

Closed

FP1 Lockout

Fast Flash

Off

Flashing Code 4

Closed

FP2 Lockout

Fast Flash

Off

Flashing Code 5

Closed

CO Lockout

Fast Flash

Off

Flashing Code 6

Closed

CO

Condensate Overflow

ESD — Emergency Shutdown
FP

Freeze Protection

HP

High Pressure

LP

Low Pressure

PM

Performance Monitor