8 Technical data
OADM 20I
6x41/S14F
6x60/S14F
6x72/S14F
6x80/S14F
6x81/S14F
Measuring range MR
30...70 mm
30...130 mm
50...300 mm
100...600 mm
200...1000 mm
Min Teach-in range
≥
2 mm
≥
3 mm
≥
5 mm
≥
10 mm
≥
20 mm
Resolution *
1)
4…20
µ
m
5…60
µ
m
0.01…0.33 mm
0.015...0.67mm
0.12...3.0 mm
Linearity error *
2)
±
12..
±
60
µ
m
±
15..
±
200
µ
m
±
0.03..
±
1.0 mm
±
0.05..
±
2.0 mm
±
0.48..
±
12.0 mm
Response time *
3)
300...900
µ
s
300...900
µ
s
300...900
µ
s
300...2800
µ
s
300…2800
µ
s
Ambient light *
4)
< 50k Lux
< 40k Lux
< 8k Lux
< 10k Lux
< 5k Lux
Typ. Temperature coefficient *
5)
±
0.015%
of MR/°C
±
0.03%
of MR /°C
±
0.03%
of MR/°C
±
0.03%
of MR/°C
±
0.06%
of MR/°C
Light source
Laser diode red, pulsed
Laser class
2
Wave length
650 nm
Laser spot *
6)
1 .. 0.2 mm
2 .. 1 mm
2 mm
2 mm
2 mm
Laser line*
7)
high
width
2 mm
1...0.2 mm
3...5 mm
2...1 mm
4...12 mm
2.5 mm
5.5...21 mm
2.5 mm
8.5...35 mm
2.5 mm
Analog output
4 – 20 mA and 0 – 10 V
Load resistor U
Out
> 100 k
Ω
Load resistor I
Out
< (+Vs – 6 V) / 0.02 A
Alarm output
PNP / max. 100 mA
Voltage supply range
12 – 28 VDC
Supply current
< 100 mA, (bei + 24V ~ 40mA)
Reverse polarity protection
yes (voltage supply only)
Short circuit protection
yes
Housing material
Die-cast zinc
Tightening torque
1.0 Nm
Protection class
IP 67
Temperature range
0°C .. +50°C (non condensing)
Storage temperature
-20°C .. +70°C
*
1)
and
*
2)
measured on white ceramic sheet
*
3)
the response time depends on the reflectivity of the object
*4)
max. sunlight on a white measuring surface
*5)
xx% of full scale measuring range / °C
*
6)
and *
7)
dimension of laser beam:
OADM 20I64xx/S14F
diameter
OADM 20I65xx/S14F
size laser beam
measuring
range
Ø – beam
height
width
measuring
range