2. Specifications

2.1 General

Measurement time

2ms / 5ms / 10ms / 20ms / 50ms / 100ms / 200ms / 500ms / 1s / 2s / 5s
(Frequency measurements might take longer than the predefined measurement
time)
AC Version

90…264 VAC (47...63 Hz) / 120VDC … 370VDC

Supply voltage

DC Version

18…36 VDC

AC Version

3000 VAC (from AC/DC power supply)

Isolation voltage

DC Version

1500 VDC (from DC/DC converter)

Isolation

Galvanic isolation between:

• Supply

• Sensor input incl. sensor supply

• Binary

input

1

• Binary

input

2

• Analog

output

1

• Analog

output

2

• Relay

outputs

• Open Collector output 1

• Open Collector output 2

• Ethernet

interface

P Min. (W)

P Max. (W)

18 VDC

3.3 6.6

24 VDC

3.4 6.7

DC Version

36 VDC

3.5 6.8

110 VAC

5.0 11.0

Power consumption

AC Version

230 VAC

8.0 14.0

18 VDC
24 VDC

DC Version

36 VDC

> 20ms

110 VAC

Power supply bridging

AC Version

230 VAC

> 20ms

AC Version

-25°C…+50°C

Operating temperature

DC Version

-40°C…+70°C

AC Version

Storage temperature

DC Version

-40°C…+85°C

AC Version

430g

Weight

DC Version

390g

Sealing to DIN
EN 60529

IP 20

2.2 Inputs

2.2.1 Sensor Inputs

An overview how different sensor can be connected is in chapter 5.1.2 Terminal A

Number 2
Frequency range (-3dB)

0.025 Hz … 50 KHz

Measurement range

Programmable within the frequency range

Measurement accuracy

0.002 %

Resolution
(Frequency)

10 ns

Input impedance

> 11.5 k

Ω

(0.1 Hz

Æ

80 k

Ω

, 1 KHz

Æ

18.5 k

Ω

, 10 KHz

Æ

16 k

Ω

, 50 KHz

Æ

11.6 k

Ω

)