beautypg.com

Dynalco SWT-2000 Speed Switch/Speed Transmitter User Manual

Page 24

background image

Operating Instructions SWT-2000

DYNALCO


20

6.7.9 Relay Outputs


To configure relay outputs go to , .

Relay configuration consists of:
Assignment, the Latch Function and the Fail safe/Not fail safe mode.






Possible relay assignment:

Latch Function: Latched / not latched
Safety function: Fail safe / Not fail safe

System limit 1

Sensor Error

System limit 2

Static S1

System limit 3

Static S2

System limit 4

Dynamic error

System limit 5

Always ON

System limit 6

Always OFF

Assignment selection

The selection box is used to choose relay assignment.

Latch Function

Defines whether a relay state should be held until reset.


Safety Function

Defines whether the relay is to operate in Fail safe (deactivate at limit) or not fail safe mode (activate at limit).

6.7.10 Open Collector Outputs


To configure Open Collector outputs go to , .

Open Collector configuration consists of:
Assignment, the Latch Function and the Fail safe/Not fail safe mode.

Possible Open Collector assignment:

System Limit 1

Static S2

System Limit 2

Dynamic error

System Limit 3

Always ON

System Limit 4

Always OFF

System Limit 5

Frequency S1

System Limit 6

Frequency S2

Sensor Error

Frequency x2

Static S1

Frequency x4


Latch Function:

Latched / not latched

Safety mode:

Fail safe

/ Not fail safe



Assignmment selection

The selection box is used to choose Open Collector assignment.


Latch Function