Operating Instructions SWT-2000

DYNALCO


7

Reaction time

Effective Measurement interval + max 6 ms

Contact resistance

50 m

Ω Max. (Initial contact)

Contact isolation

1500 VAC (coil to contact)
1000 VAC (between open contacts)

2.4.3 Open Collector Outputs

Number

2 Open Collector outputs

Type Opto-coupler

(passive)

External resistance

IC nominal = 15mA (R

Pull-up

= V / I)

Example: V = 24 V

Æ

R = 1.6 k

Ω

IC max. = 30mA

Reaction time

• As Frequency output: <30 us

• Effective Measurement interval + max 30 us

Load voltage

V = 5VDC…36VDC

Isolation voltage

1500 VAC

Functions

• May be assigned to System Limit 1..6, Sensor Alarm, Static error Sensor 1 or

2, dynamic error, always on or off.

• With or without Hold function (Reset via Binary input)

• Frequency Sensor 1 or 2, Frequency x2, Frequency x4 (subject to phase shift)

• Fail Safe or Not Fail Safe

Inverting

Open collector output frequencies are in phase with the input signal.

2.5 Data Communication

2.5.1 Ethernet

Number 1
Physical Layer

Ethernet 10Base-T, IEEE 802.3i

Max cable length

100 m

Transmission rate

10 MBit/s

Connection

Front panel, 8P8C (RJ45)

Usage

Configuration and measurement status

Protocol

Peer to Peer

Connecting cable

Use a crossover cable

2.6 Environment

2.6.1 Climatic Conditions

Standard

DIN 40 040

Operating temperature

See 2.1 General

Storage temperature

See 2.1 General

Relative Humidity

• 75% average over 1 year; to 90% for max. 30 days.

• Condensation to be avoided.

2.6.2 Electromagnetic Immunity

Electrostatic discharge

EN 61000-4-2

Contact 6 kV, air 8 kV

Electromagnetic fields

EN 61000-4-3

30 V/m, not modulated and AM 80 % with 1000Hz Sinus
wave

Fast transients

EN 61000-4-4

2 kV, repeated 5 kHz duration 15 ms period 300 ms

Slow transients

EN 61000-4-5

Line / line +/- 1kV, earth line +/- 2kV, 1 per minute

Conducted HF

EN 61000-4-6

3 V eff (180 dBuV) 10 kHz – 80 MHz

Mains frequency
Magnetic field

EN 61000-4-8

50 Hz, 100 A/m 2 minutes

Voltage dips

EN 61000-4-11

Voltage dips, short interruptions and voltage variations
immunity tests