beautypg.com

Dynalco SWT-2000 Speed Switch/Speed Transmitter User Manual

Page 23

background image

Operating Instructions SWT-2000

DYNALCO


19

6.7.8 System Limit


Go to , .

Every System Limit has the same 5 logic inputs: Sensor 1, Sensor 2, Math function, Binary input 1, Binary
input 2. A hysteresis may be applied to the first 3. Each may be inverted or selected to form part of a logical
combination or disabled. The logical combination of inputs may be OR or AND.

Sensor alarm may be additionally combined OR with the System Limit result.

Sensor 1:
Limit

low:

0.01

200.0

… 999,999

Limit

high:

0.01

300.0

… 999,999


Sensor 2
Limit

low:

0.01

400.0

… 999,999

Limit

high:

0.01

500.0

… 999,999


Math Function

Limit low:

-999,999 … 50.0 … 999,999

Limit high:

-999,999 … 100.0 … 999,999


Inversion:
Sensor

1:

Over speed

/ Under speed

Sensor

2:

Over speed

/ Under speed

Math:

Over-run

/ Under-run

Binary

input

1:

active

/ inactive

Binary

input

2:

active

/ inactive


Inclusion in logical combination:
Sensor

1:

On

/ Off

System Limit 1

Sensor

2:

On

/ Off

System Limit 2

Math:

On

/ Off

System Limit 3

Binary

input

1:

On

/ Off

System Limit 4

Binary

input

2:

On

/ Off

System Limit 4


Logical combination:
Combined

OR

/ AND


Hysteresis

Hysteresis may be definined for the first 3 inputs via upper and lower limits. If the lower limit is set higher than
the upper limit, the hysteresis is inverted.

Inversion

Every input may be inverted.

Logical combination


The box must be ticked to include the input in the logical combination.




Sensor Alarm

To OR Sensor alarm with the System Limit result the box must be ticked.