Unloading closeout – Great Plains ADC2350BE Operator Manual User Manual
Page 56

52
ADC2350/E and ADC2350B/BE
Great Plains Manufacturing, Inc.
167-085M
2012-08-01
Unloading Closeout
29. Remove pin from hand crank shaft, return hand
crank to storage position, and re-pin.
30. If storing at end of season, or having residual
material in the auger tube is a concern, reverse the
directional control on the auger until no seed
remains in the auger tube.
31. Set the tractor circuit for the auger to neutral, or shut
down tractor hydraulics completely.
Refer to Figure 37 on page 39
32. With auger circuit off, set diverter handle back
(pass-through to markers or fan).
Do not move the auger hydraulic diverter valve to the forward
position until the hydraulic circuit has been shut off at the
tractor. If the diverter is moved with hydraulics on, the drill
markers will suddenly begin moving.
Refer to Figure 62
33. Clean out auger hopper by pulling up the hopper
snap pin
and swiveling the hopper
to the side.
34. When empty, fold the auger swing arm (middle pivot
forward), and move it nearly into the cradles.
35. Swivel the auger hopper for transport or storage.
See “Storing Auger” on page 40.
36. Return auger to storage cradle. See “Storing
37. If removed, re-attach lower ladder. See “Removing
38. Wipe top and bottom of meter-box seal flanges,
making sure all material is removed. Look for
material caught between seal and flange.
39. Close clean-out and calibration doors. Close and
latch bulk hopper lids if they were open for
unloading.
Figure 62
Empty Auger Hopper
26331
1
2
1
2
Figure 63
Checking Meter Box Seals
26341