OPERATOR’S MANUAL
PM300, PM332, PM400 Planter Monitors
11001-1372-200606
ADVANCED SETUP / 31
Figure 19
Service Screen
SECURITY SCREEN
Security features allow password protection security levels to be activated
(refer to Figure 20). This prevents unauthorized personnel from modifying
key parameters in the field.
The password screen allows the operator to individually lock screens to
assure they are not modified.
To Lock and Unlock Screens:
1. Press the Display & Service key.
2. Using the Arrow keys, highlight the Security icon and press the Enter
key to enter a password.
3. Modify the digits and select the Enter key again to accept the
password.
4. Highlight the Configuration key and press Enter to navigate to the list
of screens.
5. Use the Up or Down Arrow key to highlight icon for editing.
6. Press Enter to select the Lock/Unlock icon.
7. Lock or unlock screens by pressing the Up or Down Arrow keys.
8. Press Enter key to accept Lock or Unlock.
9. Select the Escape key to return to the Password screen.
10. Highlight the padlock and select the Enter key to toggle the unlocked
state to locked. The selected screens will require input of the password
prior to modification.
M : 0 3 0 5 0 2 2 1 0 9
B : 0 2 0 5 0 3 0 7 1 4
H : 1
25.7
910.0
ac
12.8
1
2
Total hours of
operation
Total acres
covered
Hardware and
software versions
Battery voltage
Hopper Level 1 and 2
sensor status
Lift switch
status
ESCAPE
ENTER
Security icon
Up or Down Arrow keys
Enter key