Help card, Operator’s manual – Great Plains PM400 Monitor Operator User Manual
Page 18

OPERATOR’S MANUAL
PM300, PM332, PM400 Planter Monitors
11001-1372-200606
12 / QUICK START GUIDE
To perform a new calibration:
1. Measure a 400 foot (122 meter) course, clearly marking the beginning
and end.
2. Using the Arrow keys, highlight the Start softkey on the screen ( X ).
3. Begin moving the tractor forward at 2-5 mph.
4. When the tractor is even with the beginning marker, press the Enter
key to start the 400-foot calibration.
5. After the calibration has begun, the softkey on the screen will change
to a Stop ( ) softkey. Drive 400 feet and stop the vehicle.
6. Select the Enter key to stop the calibration. The new calibration factor
will be displayed on the window.
7. Once the Stop key is selected, the value will be saved upon screen
exit. Selecting the Escape key while the calibration is running will not
save the value.
8. Select either the Escape or Operate key to return to the Operate
(main) screen.
HELP CARD
The help card (Figure 7) may be cut out to provide a compact reference for
definitions, set-up screens, and general operating information.
ENTER
OPERATE
ESCAPE
Enter key
Operate key
Escape key