05 mig welding problems, 05 mig welding problems -5, Transmig 400 i – Tweco 400i Transmig User Manual
Page 45
TRANSMIG 400 i
6-5
July 18, 2008
6.05 MIG Welding Problems
Description
Possible Cause
Remedy
1 Undercut.
A Welding arc voltage too high.
A Reduce
WELD (V) control or increase the wire
feed speed.
B Incorrect torch angle.
B Adjust angle.
C
Excessive
heat
input.
C
Increase the torch travel speed and/or reduce
welding current by reducing the
WELD (V)
control or reducing the wire feed speed.
2 Lack of penetration. A Welding current too low.
A Increase welding current by increasing wire
feed speed and increasing
WELD (V) control.
B
Joint preparation too narrow or gap
too tight.
B Increase joint angle or gap.
C Shielding gas incorrect.
C Change to a gas which gives
higher penetration.
3 Lack of fusion.
Voltage too low.
Increase
WELD (V) control.
4 Excessive spatter.
A Voltage too high.
A Lower the voltage by reducing the
WELD (V)
control or increase wirespeed control.
B Voltage too low.
B Raise the voltage by increasing the
WELD (V)
control or reduce wirespeed control.
5 Irregular weld
shape.
A Incorrect voltage and current
settings. Convex, voltage too low.
Concave, voltage too high.
A Adjust voltage and current by adjusting the
WELD (V) control and the wirespeed control.
B Wire is wandering.
B Replace contact tip.
C Incorrect shielding gas.
C Check shielding gas.
D Insufficient or excessive heat input.
D Adjust the wirespeed control or the voltage
selection switches.
6 Weld cracking.
A Weld beads too small.
A Decrease travel speed.
B Weld penetration narrow and deep.
B Reduce current and voltage and increase MIG
torch travel speed or select a lower penetration
shielding gas.
C Excessive weld stresses.
C Increase weld metal strength or
revise design.
D
Excessive
voltage.
D
Decrease voltage by reducing the
WELD (V) control.
E Cooling rate too fast.
E Slow the cooling rate by preheating part to be
welded or cool slowly.
7
Cold weld puddle.
A Loose welding cable connection.
A Check all welding cable connections.
B Low Primary Voltage.
B Contact supply authority.
C Faulty rectifier unit.
C Have an accredited Cigweld Service Provider
to test then replace the faulty component.
8
Arc does not have
the crisp sound
that comes when
the wirefeed speed
and voltage are
adjusted correctly.
The MIG torch has been connected
to the wrong voltage polarity on the
front panel.
Connect the MIG torch to the positive (+)
welding terminal for solid wires and gas
shielded flux cored wires. Refer to the
electrode wire manufacturer for the
correct polarity.