Page 24

background image

TRANSMIG 400 i

4-2

July 18, 2008

3. Positive Terminal:

Welding current flows from the Power Source via heavy duty Dinse type terminal. It is

essential, however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

4. Negative Terminal:

Welding current flows from the Power Source via heavy duty Dinse type terminal. It

is essential, however, that the male plug is inserted and turned securely to achieve a sound electrical
connection.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused
in the bayonet terminal.

5. ON/OFF Switch:

This switch connects the Primary supply voltage to the inverter when in the ON position. This

enables the Power Supply.

!

WARNING

When the welder is connected to the Primary supply voltage, the internal electrical components
may be at 240V potential with respect to earth.

6. Input Cable:

The input cable connects the Primary supply voltage to the equipment.

7. 24VAC Remote Device C/B:

Push to reset. Controls the 24VAC power source for the wire feeders controlled

through the Remote Control Sockets.

8. 115VAC Remote Device C/B:

Push to reset. Controls the 115VAC power source for the wire feeders controlled

through the Remote Control Sockets.