TRANSMIG 400 i
July 18, 2008
4-7
Control Knob
• For the selected weld parameter, rotating the knob
clockwise increases the parameter.
• Rotating the knob counter-clockwise decreases the
parameter.
• A selected weld parameter value can be adjusted at any
time even while welding.
• Pushing the knob in sets the selected parameter then
displays the next parameter.
Self Diagnosis Using Error Codes
• An error code is displayed on the Digital Meter when a
problem occurs with Mains supply voltage or internal
component problems.
Save/Load Function
• A total number of 5 programs can be saved into the 400 i
memory.
SAVE
the Current Weld Parameters into Memory
• Press and HOLD the
SAVE
button for 3 seconds. Beep will
sound and Digital Meter display will show a number 1.
• Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.
After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters are loaded onto the
control panel.
LOAD
(retrieve) a Program to Control Panel
• Press and HOLD the
LOAD
button for 3 seconds. Beep will
sound and Digital Meter display will show a number 1.
• Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.
After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters are loaded onto the
control panel.