Tweco 350 4R Wirefeeder User Manual
Page 18

weldskill 250, 350 introduction
2-6
Manual 0-5182
Introduction
2.09 WeldSkill 250 MIG Power Source Specifications
Description
WeldSkill 250 MIG
Plant Part Numbers
W1003400 & W1004500
Plant Dimensions
H 1050mm x W 470mm x D 1020mm
Power Source Mass
100kg
Cooling Fan
Cooled
Energy Input (Refer NOTE below)
This Column applies to the
Factory Fitted 2.5mm
2
(20A)
Primary Lead with 15A
Supply Plug
This Column applies to a
4.0mm
2
(25A) Primary
Lead with a 25A Supply
Plug.
Input Cable Requirements
Factory Fitted
4.0mm
2
2 core
+ earth
heavy duty R90 insulation
type
Nominal Supply Voltage
240VAC
240VAC
%
±
10%
±
10
Number of Phases
1
1
Nominal Supply Frequency
50Hz
50Hz
Effective Input Current (I
1eff
)
♥
15 Amps
♥
24 Amps
Maximum Input Current (I
1max
)
33 Amps
54 Amps
Single Phase Generator Requirement
♣
8kVA
♣
13kVA
Welding Current Range
50 – 190A
50 – 270A
Open Circuit Voltage Range
22 to 46 V
22 to 46 V
MIG (GMAW)
Welding Output, 40
o
C, 10 min.
190A @ 20%, 23.5V
110A @ 60%, 19.5V
85A @ 100%, 18.3V
250A @ 20%, 26.5V
144A @ 60%, 21.2V
112A @ 100%, 19.6V
Operating Temperature Range
0ºC - 40ºC
0ºC - 40ºC
Number of Output Voltage Switch Settings
12
Protection Class
IP21S
Table 2-1 WeldSkill 250 Specification
Table 2-1 WeldSkill 250 Power Source Specification
♥ The Effective Input Current should be used for the determination of cable size & supply requirements.
Motor start fuses or thermal circuit breakers are recommended for this application. Check local require-
ments for your situation in this regard.
♣ Generator Requirements at the Maximum Output Duty Cycle.
Reduced output ratings apply with the supplied 15A primary lead. To achieve the maximum rated output
& duty cycle ratings the 20A primary lead must be replaced with a larger primary lead as specified in
section 3.04. This must be carried out be a qualified electrical tradesperson.
NOTE
Due to variations that can occur in manufactured products, claimed performance, voltages, ratings,
all capacities, measurements, dimensions and weights quoted are approximate only. Achievable
capacities and ratings in use and operation will depend upon correct installation, use, applications,
maintenance and service.