08 duty cycle – Tweco 350 4R Wirefeeder User Manual
Page 17
introduction weldskill 250, 350
2-5
Manual 0-5182
Introduction
2.08 Duty Cycle
Art# A-09909_AC
WeldSkill 250 Welding Current (amps)
Art # A-08724
Duty Cycle for 350
WeldSkill 350 Welding Current (amps)
WeldSkill 350 Welding Current (amps)
The rated duty cycle of a Welding Power Source, is a statement of the time it may be operated at its rated
welding current output without exceeding the temperature limits of the insulation of the component parts. To
explain the 10 minute duty cycle period the following example is used. Suppose a Welding Power Source is
designed to operate at a 30% duty cycle, 350 amperes at 31.5 volts. This means that it has been designed and
built to provide the rated amperage (350A) for 3 minutes, i.e. arc welding time, out of every 10 minute period
(30% of 10 minutes is 3 minutes). During the other 7 minutes of the 10 minute period the Welding Power
Source must idle and be allowed to cool. The thermal cutout will operate if the duty cycle is exceeded.