Gas Control Module: Controls & Indicators

1. MODE Selection Switch

MODE

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

PREFLOW

H

2

O

MIST

PLASMA

SHIELD

PRESSURE

PLASMA

POWER SUPPLY

GAS

FLOW

AMPERAGE

SET-UP

High Precision

Plasma Cutting System

ENABLE

DISABLE

GAS

MODE

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

O2 - AIR

O2 - O2

H35 -N

2

F5 - N

2

AIR - AIR

N

2 -

H

2

O

N

2 -

N

2

Art # A-04765

9

9

GCM

2010

• Normally in the RUN position during torch operation.

• In the SET PREFLOW position, Air or N2 travels to the torch. The Preflow valve remains open for 2 minutes

to allow the operator to adjust flow pressure.

• In the SET PLASMA & SHIELD position, gases travel to the torch. The Preflow valve at the torch remains open

for 2 minutes to allow the operator to adjust flow pressures and rates.

• In the TEST position, gases fill the torch leads. The display shows the pressure of the plasma gas while

flowing. After 1 minute the Module shuts off the valves at the torch.