2-2

SPECIFICATIONS

Specifications & Electrical Requirements

Max OCV (U

0

)

380 vdc

Minimum Output Current

10 Amps

Max Output Current

150 Amps

Output Voltage

60 - 230 vdc

Duty Cycle Rating

100% @ 150A, 180V

Ambient Temperature
for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 100 A DC Output

Cooling

Forced Air (Class F)

UItraCut 150 Specifications & Design Features

Input

Power Input

Current

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

60

23

105

125

#4

2

230

60

24

98

110

#4

2

400

50

28

58

75

#4

1

400 (CE)

50

28

58

75

#4

1

460

60

26

57

75

#4

1

2

Extra Hard Usage Type G, G-GC, W

Line Voltages with Suggested Circuit Protection and Wire Sizes

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

Ultra-Cut 150 Power Supply

Suggested Sizes (See Note)

Based on National Electric Code and Canadian Electrical Code

System Component Layout

Primary power

Work

CNC

Remote

Arc

Starter

Art # A-07233

Torch

Coolant Supply

Coolant Return

Control Cable

Pilot

Return

Coolant Supply

Coolant Return

Plasma Gas

Shield Gas

Work Cable

Fiber
Optic

Cable

Control

Cable

Gas Control

Module

Power
Supply

Torch

Valve

Assembly

Positioning Tube

Plasma Gas

Preflow Gas

Water Shield

Shield

Shield Gas

Negative

Pilot

Return

Control Cable

100’ / 30.5 m Maximum Length

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Shield

H

Q

R

T

S

A

B

C

D

E

P

F

K

L

O

F1

F

I

J

G

175’ / 53.3 m Maximum Length