Specifications & electrical requirements, System component layout – Tweco 150 Ultra-Cut User Manual
Page 16
Manual No. 0-4800
2-2
SPECIFICATIONS
Specifications & Electrical Requirements
Max OCV (U
0
)
380 vdc
Minimum Output Current
10 Amps
Max Output Current
150 Amps
Output Voltage
60 - 230 vdc
Duty Cycle Rating
100% @ 150A, 180V
Ambient Temperature
for Duty Cycle Rating
104F° (40°C)
Operating range
14°F to 122°F (-10°C to + 50°C)
Power Factor
0.70 @ 100 A DC Output
Cooling
Forced Air (Class F)
UItraCut 150 Specifications & Design Features
Input
Power Input
Current
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
208
60
23
105
125
#4
2
230
60
24
98
110
#4
2
400
50
28
58
75
#4
1
400 (CE)
50
28
58
75
#4
1
460
60
26
57
75
#4
1
2
Extra Hard Usage Type G, G-GC, W
Line Voltages with Suggested Circuit Protection and Wire Sizes
1
Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW
Ultra-Cut 150 Power Supply
Suggested Sizes (See Note)
Based on National Electric Code and Canadian Electrical Code
System Component Layout
Primary power
Work
CNC
Remote
Arc
Starter
Art # A-07233
Torch
Coolant Supply
Coolant Return
Control Cable
Pilot
Return
Coolant Supply
Coolant Return
Plasma Gas
Shield Gas
Work Cable
Fiber
Optic
Cable
Control
Cable
Gas Control
Module
Power
Supply
Torch
Valve
Assembly
Positioning Tube
Plasma Gas
Preflow Gas
Water Shield
Shield
Shield Gas
Negative
Pilot
Return
Control Cable
100’ / 30.5 m Maximum Length
125’ / 38.1 m Maximum Length
175’ / 53.3 m Maximum Length
Shield
H
Q
R
T
S
A
B
C
D
E
P
F
K
L
O
F1
F
I
J
G
175’ / 53.3 m Maximum Length