beautypg.com

Tweco 150 Ultra-Cut User Manual

Page 49

background image

Manual No. 0-4800

3-27

INSTALLATION

Installation

The Remote Arc Starter must be installed in a suitable location near the torch head. If the Arc Starter is mounted
to a gantry or to any other support subject to motion or vibration, fasten the Arc Starter to the support securely.

1. Loosen, but do not remove, the lower screws securing the cover to the Arc Starter. Remove the upper

screws securing the Cover Panel to the Arc Starter.

NOTE

A ground wire connects the cover to the Arc Starter base. This wire must remain in place.

2. Remove the Cover Panel from the Arc Starter.

Art # A-07029

Lower screws

Upper screws (4 per side)

Cover

Ground Wire

Cover Removal

3. Position the Arc Starter on a flat, horizontal mounting surface.