4. Use the removal tool to hold the cartridge assembly, while turning the shield cup onto the cartridge

assembly. When this group is fully assembled, the shield should protrude from the front of the shield
cup 0.063" to 0.083" (1.6 - 2.1 mm). Without this protrusion the shield cup is not properly tightened
onto the cartridge assembly.

5. Take the removal tool off the cartridge. Fit the cartridge assembly onto the torch head. The cartridge

should seal to the large O-ring on the torch body as shown. If the cartridge does not seal on the O-ring, the
cartridge is not fully tightened.

CAUTION

Do not force the cartridge if it will not fully tighten. Remove the cartridge and gently clean the threads
on the torch head body with a wire brush. Apply oxygen-compatible lubricant (supplied with the torch)