Connect Input Power and System Ground Cables

1. Carefully cut back the outer sheath on the primary input power cable to expose the individual cords. Cut back

the insulation on the individual cords. Route the cable upward through leads bracket at the bottom of the rear
panel, then through the connections cover support panel on the rear panel of the power supply.

2. Install ring tongue terminals on the individual cords. Fasten the terminals to the individual cords securely.

3. Connect the individual cords as shown. Connect the power cable ground cord to the ground terminal block.

CAUTION

The clear connections cover must remain in place.

4. Pass a system ground cable through the same opening in the connections cover support panel as the input

power cable. Connect the cable to the ground terminal block on the power supply rear panel. Refer to the
Ground Connections Section for full details and procedures on proper system grounding.

PILO

T

WORK

TORCH

AC INPUT

Input power cable

System Ground Cable

Ground Terminal Block

Connections Cover
Support Panel

Input power cable ground

System Ground Cable

Art # A-07659

to Remote Arc Starter

Connections Cover

Connection Panel

Leads Bracket

to Remote Arc Starter

L1

L2

L3

L1

L2

L3

4. Re-install the connections cover on the power supply. Snug the hardware securely by hand. Do not over-

tighten.