Setting the frequency – Bird Technologies SA-4000 User Manual
Page 28
![background image](/manuals/583803/28/background.png)
Bird Site Analyzer
18
Setting the Frequency
Frequencies can be set manually or chosen from a list
of presets. If the start, stop, center, or span is
manually changed, the band will become “Custom”.
☞
NOTE: Changing the frequency settings will
automatically turn calibration off. Always set
the frequency before calibrating the unit.
☞
NOTE: If a frequency outside of the Site
Analyzer’s range is entered, the unit’s minimum or
maximum frequency will be set instead.
Press from
Measure
Match Mode
Press to
display the
frequency
settings
780.00
MHz
2500.00
Measure Match Mode
Start:
780.00
MHz
Stop: 2500.00 MHz
99.99
1.00
V
S
W
R
Freq
Scale
Limit
Line
Cable
Loss
Center: 1640.00 MHz
Span: 1720.00 MHz
Band List: Custom
Freq
Scale