Bird Site Analyzer

16

y

Press the CALIBRATE key.

y

Attach the open standard.

Press the OPEN key.

Wait for a “beep” and for the trace to scroll before

continuing.

y

Attach the short standard.

Press the SHORT key.

Wait for a “beep” and for the trace to scroll before

continuing.

y

Attach the load standard.

Press the LOAD key.

Wait for a “beep” and for the trace to scroll before

continuing.

y

Press the CAL DONE key. New coefficients are

calculated. The Site Analyzer is now calibrated.

NOTE: Now is a good time to save the setup.
Saving after calibration will save the new
calibration coefficients. See “Save Setup”, page 75.