background image

Introduction

5

1.

Soft Keys

Activates the function described directly to the

right of the key.

2.

Mode Keys

Mode

Activates the mode menu. This menu allows the

user to select Measure Match, Fault Location,

Measure Power, or Utilities modes.

Config

Activates the configuration menu for the current

mode. This menu provides access to the variable

measurement parameters (e.g. frequency band,

distance, and units).

Calibrate

Activates the calibration menu.

Marker

Activates the marker menu. This menu allows

the user to turn markers is on or off and to move

the active marker.

3.

Numeric Keys

Enter numeric data into the selected item, or as

defined by the function description.

4.

Escape Key

During:

Menu Selection

Backs up one menu level.

Data Entry

Exits data entry without changing the value.

5.

Enter Key

During

List Selection

Selects the highlighted item in the list.

Data Entry

Exits data entry, changing the value.

6.

Cursor Keys

Left Arrow

During:

Data Entry

Deletes previously entered data one character at

a time.

Marker Control

Moves active marker left one point at a time.

All other times

As defined by the function description.