Rockwell Automation 20D PowerFlex 700H/S Frame 12 Replacement Power Structure User Manual
Page 24
24
PowerFlex® 700S and 700H Frame 12 Replacement Power Structures
ASIC Feedback Board Connections - Power Structure #1
Note: Refer to
for ASIC Feedback Board termination points.
ASIC Feedback Board Connections - Power Structure #2
Figure 9 Termination Points on the 700H Star Coupler Fiber Optic Interface Board
Connect this component :
termination point . . .
to this component : termination point
ASIC Feedback Board: X900
ASIC Board Power Structure #1: X26
ASIC Feedback Board: H900, H901,
H902 (fiber optic bundle)
Star Coupler Fiber Optic Interface Board: H21, H22, H23
ASIC Feedback Board: H903
Star Coupler Fiber Optic Interface Board: H8
Connect this component :
termination point . . .
to this component : termination point
ASIC Feedback Board: X900
ASIC Board Power Structure #2: X26
ASIC Feedback Board: H903
Star Coupler Fiber Optic Interface Board: H18
H8
H7
H6
H5
H4
H3
H2
H1
H18
H17
H16
H15
H14
H13
H12
H11
H23
H22
H21
X2