Appendix a - technical specifications, Appendix a, Technical specifications – Rockwell Automation GV3000 AC Pwr Module Ver. 5.0 Hardware Ref, Installation, and Troubleshooting User Manual
Page 91

AĆ1
Appendix A
Technical Specifications
Table A.1 Ć Service Conditions
AĆC Line Distribution System Capacity (maximum)
for 460 VAC Units
1000KVA, threeĆphase with 25,000 amps symmetrical
fault current capacity with a line impedance of less
than 8%
Control Method
AllĆdigital vector, sinusoidal pulseĆwidthĆmodulated
(PWM)
Displacement Power Factor
0.96
Line Frequency
50/60Hz (+2 Hz)
Line Voltage Variation
-10% to +10%
Line Dip Ride Through
Maximum 500 milliseconds Ć vector
Adjustable up to 999.9 seconds (See P.042) Ć V/Hz
Motor Lead Lengths
76 meters (250 feet) total
Analog Speed Reference Accuracy
0.5%
Acceleration Adjustment Range
0.1 to 999.9 seconds (within the ability of current)
Carrier Frequency
2 Hz, 4 Hz, or 8 Hz, softwareĆselectable
Current Limit Adjustment
U.006 to 150% (based on drive nameplate rating) Ć
vector
50% to 110% (based on drive nameplate rating) Ć V/Hz
Service Factor
1.0
Speed Adjustable Range
From 0 RPM to maximum speed
Speed Regulation
Vector Ć 0.01% long term steady state
V/Hz Ć motor slip dependent
Speed Reference Resolution
1 RPM with local keypad, -4095 to +4095 counts with
a network or serial reference
Torque Control Response
180 to 220 Hz
Torque Linearity
+3% with optimal parameter setting (typical) (see
parameter U.005)
Table A.2 Ć Ambient Conditions
Condition
Specification
Operating Temperature (Ambient)
0_ to +40_ C (32_ to 104_F)
Storage Temperature (Ambient)
-40_āto +65_C (-40_ to +149_F)
Humidity
5 to 95% (nonĆcondensing)