beautypg.com

Rockwell Automation FactoryTalk Metrics Line Edition Administrators Guide User Manual

Page 36

background image

F

ACTORY

T

ALK

M

ETRICS

L

INE

E

DITION

A

DMINISTRATOR

S

G

UIDE

32

• •

„

Database Password. Enter the user’s password for the SQL Server database.

6. To test the connection, click Test Connection. When the connection is successful,

click OK.

7. Click Apply and then click Yes to restart the server.

8. When the warning message appears regarding not rebooting until the Information

Services Manager has started, click OK. The database will be initialized with the
RSBizWare schema for FactoryTalk Metrics. When this is complete, the message
“The server is running” appears at the top of the window.

9. To associate the Metrics Server Manager, under the Servers tree item, right-click the

Information Services Manager tree item and select Associate Metrics Server
Manager
. Complete the Service Console Registration dialog box to associate the
Metrics Server Manager. Click the Metrics Server Manager tree item and complete
the Database Connection Properties in the pane on the right.

Use the DSN, user

name, and password that you used in step 5.

A

SSIGNING

USER

PRIVILEGES

,

LICENSING

,

AND

ACTIVATION

The FactoryTalk Metrics product activations that have been purchased must be assigned
to the server where the product is installed. In this section you will also import the
FactoryTalk users into the Service Console and assign user licenses and privileges. For
more information, refer to the RSBizWare Administrator’s Guide.

1. To assign activations to the Information Services Manager, open the Security

Services Manager, Administration, and Activations tree items. Select the desired
activations and click Assign an Activation to assign it to the Information Services
Manager. You will need to assign at least one Metrics Server Manager activation, at
least one FactoryTalk Metrics Author activation, and at least one RSBizWare Runtime
activation.

2. To synchronize the FactoryTalk Directory users with the RSBizWare database, under

the Administration tree item, select Users and Groups and click Refresh at the
bottom of the right pane. Any users or groups you created earlier will now appear.

3. To grant privileges to a user, select the user who to whom you want to grant

permission to configure FactoryTalk Metrics LE (for example, FTAuthor) and click
Edit User Properties. The Security Control dialog box appears.

For more information on completing the Data Connection Properties dialog box, click Help.

For more information on configuring the RSBizWare Service Console, refer to the
RSBizWare Administrator’s Guide.

FTMLE Admin Guide.book Page 32 Friday, August 8, 2008 8:28 AM