beautypg.com

Rockwell Automation 2099-BMxx-S Kinetix 7000 Drive Systems Design Guide User Manual

Page 20

background image

20

Rockwell Automation Publication GMC-RM007A-EN-P - September 2011

Kinetix 7000 Drive Systems

Kinetix 7000 (400V class) Drives/MP-Series Low Inertia Motor Curves (continued)

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

0

2000

1000

500

1500

160

0

0

20

177

40

354

60

531

80

708

1416

140

1239

120

1062

100

885

2099-BM06 and MPL-B680D

Torque

(N•m)

Torque
(lb•in)

120

100

80

60

40

20

0

1062

885

708

531

354

177

0

Speed (rpm)

0

2000

3000

1000

500

1500

2500

2099-BM06 and MPL-B680F

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

0

2000

1000

500

1500

160

0

0

20

177

40

354

60

531

80

708

1416

140

1239

120

1062

100

885

2099-BM06 and MPL-B860D

Torque

(N•m)

Torque
(lb•in)

0

2099-BM07 and MPL-B880C

442

885

1328

1770

2213

0

50

100

150

200

250

Speed (rpm)

0

1500

1000

500

1250

750

250

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

0

2000

1000

500

1500

160

0

0

20

177

40

354

60

531

80

708

1416

140

1239

120

1062

100

885

2099-BM07 and MPL-B880D

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

0

300

600

0

900

2099-BM06 and MPL-B960B

1200

442

885

1328

1770

2213

0

0

50

100

150

200

250

= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage