Rockwell Automation 2711E-ND7 PanelView File Transfer Utility User Manual User Manual
Page 55

3–9
Uploading 1000e/1200e/1400e Application Files and Alarm History Files
Box
Data
Alarm Trigger
Signed long integer value
Alarm Message
The alarm message associated with the trigger value
Message delimited by a pair of double quotes
Double quote character (
) in the message text is
translated to 2 double quotes (
).
For Version 02.00.00 and later applications, the
character sequence \n (backslash-n) in the message text
is translated to \\n
For Version 02.00.00 and later applications, the newline
character in the message text is translated to a
backslash character followed by the letter n (\n).
Trigger Date
Each field is separated by a forward slash.
4-digit year (1980 to 2043)
2-digit month (1 to 12)
2-digit day (1 to 31)
Trigger Time
Each field is separated by a colon.
2-digit hour (0 to 23)
2-digit minute (0 to 59)
2-digit second (0 to 59)
Acknowledge Date
Each field is separated by a forward slash. If the alarm is
not acknowledged, no text follows the alarm event data.
4-digit year (1980 to 2043)
2-digit month (1 to 12)
2-digit day (1 to 31)
Acknowledge Time
Each field is separated by a colon. If the alarm is not
acknowledged, no text follows the alarm event data.
2-digit hour (0 to 23)
2-digit minute (0 to 59)
2-digit second (0 to 59)
Refer to the PanelBuilder 1400e Configuration Software for
Windows User Manual for information about message formats and
limits.