beautypg.com

Rockwell Automation 2711P Software Development Kit User Manual User Manual

Page 55

background image

Publication 2711P-UM005A-EN-P - March 2007

PanelView Plus CE-Specific Extensions to the WinCE API 55

Parameters:

dwTimerNumber

The Timer Number is 0 based; i.e., if 2 timers are present on the
system, they are timer 0 and timer 1. When specifying a critical timer,
the flag USERTIMER_CRITICAL must be or’d with the Timer Number.
The range is 0 to MAX_TIMER_NUMBER.

dwCount

A DWORD value that sets the countdown value and starts the timer.
The frequency of the timer is the last frequency returned from
UserTimerRequestFrequency().

dwMode

When FALSE (zero), the timer operates as a one shot. Otherwise,
when TRUE (non zero), the timer operates in periodic mode.

Return Values:

Same as Table .

Remarks:

This API is an extension of the UserTimerSet() function in that it
allows the timer to be configured for periodic or one-shot operation.

Any count in progress is aborted by this function.

USER_TIMER_SET_FAILED indicates that the count may be beyond
the hardware capabilities of the timers and may be out of range, or
the frequency had not been set.

Portability:

This function is specific to the PanelView Plus CE.

Requirements:

Runs On

Version

Defined In

Link To

PanelView Plus CE

All

usertimers.h

usertimers.lib