Rockwell Automation 2094-BMxx-M Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions User Manual
Page 4

4 Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules
Rockwell Automation Publication 2094-IN011D-EN-P - August 2013
Setting the Ground Jumper in Ungrounded Power Configurations
Setting the ground jumper is necessary only when using an ungrounded or high-impedance
grounded power configuration. Setting the jumper involves removing the IAM power module
from the power rail, opening the IAM module, and moving the jumper.
Setting the ground jumper is best done when the IAM power module is removed from the power
rail and placed face-up on a solid surface equipped as a grounded static-safe workstation.
To remove the IAM power module from the power rail, refer to the Kinetix 6200 and
Kinetix 6500 Modular Servo Drives User Manual, publicatio
.
When using ungrounded input power in common-bus configurations, use this table to
determine where to set the ground jumper.
Ground Jumper to Set
IMPORTANT
If you have grounded power distribution, you do not need to set the ground jumper. Go to
Install the IAM/AM Power Modules
.
ATTENTION: To avoid personal injury and/or damage to equipment, remove the IAM power
module from the power rail before setting the ground jumper.
By setting the ground jumper for ungrounded power configurations, you no longer maintain
line-to-neutral voltage protection.
ATTENTION: This drive contains electrostatic discharge (ESD) sensitive parts and assemblies.
You are required to follow static-control precautions when you install, test, service, or repair
this assembly. If you do not follow ESD control procedures, components can be damaged. If
you are not familiar with static control procedures, refer to Guarding Against Electrostatic
Damage, publication
, or any other applicable ESD awareness handbook.
Leader Drive
Follower Drive
Set the Jumper in This Drive
Kinetix 6200\6500 IAM module
Kinetix 6200\6500 IAM module
Leader drive
Kinetix 6200\6500 IAM module
Non-Kinetix 6200\6500 drive
Leader drive
Non-Kinetix 6200\6500 drive
Kinetix 6200\6500 IAM module
Follower drive (if no setting exists in the
leader drive)