5. Gently push the module against the power rail connectors and into the final mounting
position.
6. Use 2.26 N•m (20 lb•in) torque to tighten the mounting screws.
7. Repeat
step 1
through
step 6
for each AM, IPIM, shunt, or slot-filler module in your
Bulletin 2094 drive system.
IMPORTANT
There are two mounting screws when mounting 2094-BC04-M03-M, and
2094-BC07-M05-M (double-wide) IAM modules, and 2094-BM03-M and
2094-BM05-M (double-wide) AM modules.
Power Rail
Bracket secured in slot.
IAM or AM Power Module, IPIM,
Shunt, or Slot-filler Module
(IAM power module is shown)
Mounting Screws
Bottom front view of
IAM module.
Bottom front view of
AM, shunt, or
slot-filler module
(AM module is shown).