7 - specifications, Chapter 7, Specifications – Rockwell Automation 1784-PCIC ControlNet PCI Communication Interface Card Installation Instructions User Manual
Page 51: Chapter

Publication 1784-IN003D-EN-P - January 2006
Chapter
7
Specifications
PCI local bus
Compliant to PCI revision 2.2.
The 1784-PCIC and 1784-PCICS cards are compatible with 5V and 3.3V PCI
slots, 32-bit and 64-bit PCI slots, and PCI-X slots.
Attention: The 1784-PCIC and 1784-PCICS cards are not compatible with PCI
Express and should not be inserted into a PCI Express slot.
Mechanical form factor, H x L
Universal PCI 32-bit short card
10.7 cm (4.2 in.) x 16.5 cm (6.5 in.) L
Driver compatibility
Microsoft Windows XP with Service Pack 1 or higher
Microsoft Windows 2000 with Service Pack 4 or higher
Microsoft Windows 98
Microsoft Windows Me
Software compatibility
Rockwell Software RSLinx software, version 2.42.00 or later
Operational temperature
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
0...55
°
C (32...131
°
F)
The operating parameters describe the environment within the PCI slot.
Refer to the documentation for your computer for environmental
requirements. This card should not exceed those specifications.
Storage temperature
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock):
-40...85
°
C (-40...185
°
F)
Relative humidity
IEC 60068-2-30 (Test Db, Un-packaged Nonoperating Damp Heat):
5...95% noncondensing
Vibration
IEC 60068-2-6 (Test Fc, Operating):
2g @ 10...500Hz
Operating shock
IEC 60068-2-27 (Test Ea, Unpackaged Shock):
30 g
Non-operating shock
IEC 60068-2-27 (Test Ea, Unpackaged Shock):
50 g
Emissions
CISPR 11:
Group 1, Class A
ESD immunity
IEC 61000-4-2:
6 kV contact discharges
8 kV air discharges
Radiated RF immunity
IEC 61000-4-3:
10V/m with 1 k Hz sine-wave 80%AM from 80 MHz...2000 MHz
10V/m with 200 Hz 50% pulse 100%AM at 900 MHz
10V/m with 200 Hz 50% pulse 100%AM at 1890 MHz