DeviceNet Explicit Messaging 99
Any time the error code is non-zero, the DEM error (ER) bit is set.
CIP Response Error Codes
Numeric Code
Name
Description
02H
Resource unavailable
A needed resource was not available
08H
Service unsupported
Service is not defined or implemented for this class/instance
09H
Invalid attribute value
Data is invalid for the specified attribute
0BH
Already in requested state
Object is in the requested state - redundant request
0CH
Object state conflict
Not allowed with object in present state
0EH
Attribute cannot be set
Read-only attribute
0FH
Privilege violation
A permission/privilege check failed
10H
Device state conflict
Not allowed with device in present state
11H
Reply too big
Reply larger than buffer allocated when connection was established
13H
Too little data
Request included insufficient data
14H
Attribute not supported
Attribute number is incorrect
15H
Too much data
Request included extra data
16H
Object does not exist
Class/instance numbers are incorrect
18H
No stored attribute data
Attribute data was not saved prior to this request
19H
Store operation failure
Attribute data was not successfully saved
1FH
Vendor-specific error
Second byte may offer details - refer to vendor documentation
20H
Invalid parameter
Parameter associated with request is invalid
D0H
Reserved and
service-specific errors
Used only when none of the standard error codes supplemented by the second byte
accurately describes the problem
FFH