Transmit string data assemblies -23, Transmit string data assemblies – Rockwell Automation 1734-485ASC POINT I/O ASCII User Manual User Manual
Page 49
Publication 1734-UM009B-EN-P - July 2003
Configuring Your ASCII Module 2-23
Transmit String Data Assemblies
Transmit String Data Assemblies are the formats of the data you will
send from the ASCII module – array, short_string or string – to the
DeviceNet master. Which one you choose depends on your
application, and will modify the format of the data field.
Table 2.8 Transmit Data Format - Array Data Type
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5-X
Byte X+1
(Max = 132)
Next RX ID Byte
(Handshake Mode
Only)
Transaction ID Byte
Reserved
Reserved
ASCII Data
(max 128 bytes)
End of String
Delimiter or Last
Data Byte
Table 2.9 Transmit Data Format - Short_String Data Type
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5-X
Byte X+1
(Max = 132)
Next RX ID Byte
(Handshake Mode
Only)
Transaction ID Byte
Reserved
Length
ASCII Data
(max 128 bytes)
End of String
Delimiter or Last
Data Byte
Table 2.10 Transmit Data Format - String Type
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5-X
Byte X+1
(Max = 132)
Next RX ID Byte
(Handshake Mode
Only)
Transaction ID Byte
Length (LSB)
Length (MSB)
ASCII Data
(max 128 bytes)
End of String
Delimiter or Last
Data Byte