7.6 Run
mode
Start communication with the 931U‐C9C7C‐BC
1
Connect the 931U‐C9C7C‐BC to a Power supply.
2
Connect the 931U‐C9C7C‐BC with the 931U‐
CABLE to an available USB port on the PC.
3
Start the 931U‐C9C7C‐BC Configurator Software.
4
Input configuration
Select the input value.
5
Output configuration
Select the output value.
6
Alarm configuration
Set the alarm relay behaviour.
7
Send configuration to 931U‐C9C7C‐BC.
The button "Save to Instrument” transmits the
new configuration to the 931U‐C9C7C‐BC.
8
Enter Password
Enter your password (the default password is
0000).
9
Read Values
With the button "Read Values” the actual values
of the 931U‐C9C7C‐BC are displayed in the win‐
dow "Running values”.
If the button "Read Continuous” is activated the
values are updated every second (monitoring).
10
Read from Instrument
To check the current configuration in the con‐
nected 931U‐C9C7C‐BC click on the "Read from
instrument” button.
Running values
• Input: 931U‐C9C7C‐BC input value in percent.
• Output: 931U‐C9C7C‐BC output value in percent.
• CJC Temperature: This the temperature in Centi‐
grade or Fahrenheit at the cold junction point in
the 931U‐C9C7C‐BC.
• Alarm1: Shows the status of the first alarm relay
-
LED = red = relay switched on (alarm)
-
LED = off = relay switched off (no alarm)