Rockwell Automation 20D-P2-SLBO PowerFlex 700S Drive Phase II Control SynchLink Board User Manual

Synchlink, Board for powerflex, 700s drives with phase ii control

background image

Installation Instructions

20D-IN010B-EN-P

SynchLink

Board for PowerFlex

®

700S Drives with Phase II

Control

What This Kit Contains

Verify that your kit contains the items listed in the following table. If your kit
does not contain the correct items, contact your Rockwell Automation sales
representative.

Tools That You Need

• Phillips

®

screwdriver

• POZIDRIV® screwdriver
• Standard (flat blade) screwdriver

Phillips

®

and POZIDRIV® are registered trademarks of Phillips Screw Company

ATTENTION: To avoid an electric shock hazard, verify that the voltage on
the bus capacitors has discharged before performing any work on the
drive. Measure the DC bus voltage at the +DC & –DC terminals of the
Power Terminal Block (DC+ & DC- in high power drives). The voltage must
be zero.

ATTENTION: HOT surfaces can cause severe burns. Do not touch the
heatsink surface during operation of the drive. After disconnecting power
allow time for cooling.

ATTENTION: Hazard of permanent eye damage exists when using optical
transmission equipment. This product emits intense light and invisible
radiation. Do not look into module ports or fiber-optic cable connectors.

ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive
parts and assemblies. Static control precautions are required when
installing, testing, servicing or repairing this assembly. Component
damage may result if ESD control procedures are not followed. If you are
not familiar with static control procedures, reference A-B publication
8000-4.5.2, “Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.

Quantity:

Description

1

SynchLink Board

1

“Stacker” connector

2

Screws

2

Stand-offs