Adapter Parameters
20-COMM-M Modbus/TCP Adapter User Manual
Publication 20COMM-UM014C-EN-P
24 [DPI I/O Cfg]
Sets the I/O that is transferred through the adapter.
Default:
xxx0 0001
Bit Values:
0 = I/O disabled
1 = I/O enabled
Type:
Read/Write
Reset Required: Yes
25 [DPI I/O Act]
Displays the I/O that the adapter is actively
transmitting. The value of this parameter will usually be
equal to the value of Parameter 24 - [DPI I/O Cfg].
Default:
xxx0 0001
Bit Values:
0 = I/O disabled
1 = I/O enabled
Type:
Read Only
26 [Flt Cfg Logic]
Sets the Logic Command data that is sent to the drive
if Parameter 23 - [Comm Flt Action] is set to “4”
(Send Flt Cfg) and communications are disrupted.
The bit definitions will depend on the product to which
the adapter is connected. See
or the
documentation for the drive being used.
Default:
0000 0000 0000 0000
Minimum:
0000 0000 0000 0000
Maximum:
1111 1111 1111 1111
Type:
Read/Write
Reset Required: No
27 [Flt Cfg Ref]
Sets the Reference data that is sent to the drive if
Parameter 23 - [Comm Flt Action] is set to “4” (Send
Flt Cfg) and communications are disrupted.
Default:
0
Minimum:
0
Maximum:
4294967295
Type:
Read/Write
Reset Required: No
Important: If the drive uses a 16-bit
Reference, the most significant word of
this value must be set to zero (0) or a
fault will occur.
28
29
30
31
32
33
34
35
[Flt Cfg A1 In]
[Flt Cfg A2 In]
[Flt Cfg B1 In]
[Flt Cfg B2 In]
[Flt Cfg C1 In]
[Flt Cfg C2 In]
[Flt Cfg D1 In]
[Flt Cfg D2 In]
Sets the data that is sent to the Datalink in the drive if
Parameter 23 - [Comm Flt Action] is set to “4” (Send
Flt Cfg) and communications are disrupted.
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Default:
0
Minimum:
0
Maximum:
4294967295
Type:
Read/Write
Reset Required: No
Important: If the drive uses 16-bit
Datalinks, the most significant word of
this value must be set to zero (0) or a
fault will occur.
36 [Web Enable]
Displays the setting of the adapter Web Pages Switch
(SW2 in
) when the adapter was last reset.
Default:
0 = Disabled
Values:
0 = Disabled
1 = Enabled
Type:
Read Only
Parameter
No. Name and Description
Details
Bit
Definition
No
t Us
ed
No
t Us
ed
No
t Us
ed
Da
ta
link
D
Da
ta
link
C
Da
ta
link
B
Da
ta
link
A
Cmd/Ref
Default
x
x
x
0
0
0
0
1
Bit
7
6
5
4
3
2
1
0
Bit
Definition
Not Used
Not Used
Not Used
Dat
alink D
Dat
alink C
Dat
alink B
Dat
alink A
Cmd/
Ref
Default
x
x
x
0
0
0
0
1
Bit
7
6
5
4
3
2
1
0