Dip Switch Settings
The following tables describe settings for DIP switch arrays S1 and
S2. Note that changes made to these settings take effect only
after a power cycle.
Table 20: DIP Switch Array S1 Settings on the Main PCB
Table 21: DIP Switch Array S2 Settings for 2-Wire (default)/4-Wire
Communication (on extension PCB)
Function
DIP switch array S1
(0: OFF, 1: ON, X: not relevant)
8
7
6
5
4
3
2
1
Default
0
0
0
0
0
0
0
0
Offset to address: 0 (00 Hex)
X
X
X
X
0
0
0
0
Offset to address: 1 (01 Hex)
X
X
X
X
0
0
0
1
Offset to address: 2 (02 Hex)
X
X
X
X
0
0
1
0
Offset to address: 3 (03 Hex)
X
X
X
X
0
0
1
1
Offset to address: 4 (04 Hex)
X
X
X
X
0
1
0
0
Offset to address: 5 (05 Hex)
X
X
X
X
0
1
0
1
Offset to address: 6 (06 Hex)
X
X
X
X
0
1
1
0
Offset to address: 7 (07 Hex)
X
X
X
X
0
1
1
1
Offset to address: 8 (08 Hex)
X
X
X
X
1
0
0
0
Offset to address: 9 (09 Hex)
X
X
X
X
1
0
0
1
Offset to address: 10 (0A Hex)
X
X
X
X
1
0
1
0
Offset to address: 11 (0B Hex)
X
X
X
X
1
0
1
1
Offset to address: 12 (0C Hex)
X
X
X
X
1
1
0
0
Offset to address: 13 (0D Hex)
X
X
X
X
1
1
0
1
Offset to address: 14 (0E Hex)
X
X
X
X
1
1
1
0
Offset to address: 15 (0F Hex)
X
X
X
X
1
1
1
1
Baud rate 19,200 Baud
X
X
0
0
X
X
X
X
Baud rate 2,400 Baud
X
X
0
1
X
X
X
X
Baud rate 9,600 Baud
X
X
1
0
X
X
X
X
Baud rate 57,600 Baud
X
X
1
1
X
X
X
X
Reset to default
1
X
X
X
X
X
X
X
Function
DIP switch array S2
4
3
2
1
Default
0
1
0
0
Terminating resistor (135
)OFF
X
X
X
0
Terminating resistor (135
) ON
X
X
X
1
Terminating resistor 4-wire OFF
X
X
0
0
Terminating resistor 4-wire ON
X
X
1
1
Rx 2-wire
0
1
0
X
Rx 4-wire
1
0
X
X
Functional Description—CAN Model
Figure 8: CAN Board with Pin Locations, Teach Button
The allocation of pins on the main connector, J2, for use with the
CAN controller model is described below.
Table 22: J2 Pin Listings
Pin
Signal
Description
Remarks
1
0V DC
Power
—
2
+24V DC
Power
—
3
Ground
Ground
—
4
Not connected
Not connected
—
5
In 2
Trigger and hold
See User Manual
6
In 1
Not used
Not used
7
Out 2
Light array interrupted
0V DC = interrupted
24V DC = not interrupted
8
Out 1
Overhang
0V DC = overhang
24V DC = no overhang
Or over-height (special function)
In 2
PNP
NPN
PNP
NPN
D7 LED - Power
CAN
Extension
PCB
D3 LED Out 1
D4 LED Out 2
D8 LED
D10 LED
D6 LED In 2
D5 LED In 1
RJ45 Connector
Emitter
RJ45 Connector
Receiver
D2 LED
D1 LED
In 1
Pot 2
Pot 1
Removable
Spring-Loaded
Connector
Input
Logic
Jumpers
S1
S2
J2
J12
J13
Out 1
Out 2
In 1
In 2
n. c.
Earth.
24 VDC