Functional description—rs 485 comm. model – Rockwell Automation 45MLA Controller Installation Instructions User Manual
Page 10

10
Functional Description—RS 485 Comm. Model
Figure 6: RS485 Control Unit Extension PCB
Pin Listings
The allocation of pins on the main connector, J2, for use with the
RS485 controller model is described below.
Table 17: J2 Pin Listings
The following table describes the connectivity of connector J16,
the RS485 connection, which is located on the extension PCB.
Table 18: J16 Pin Listings
Pin
Signal
Description
Remarks
1
0V DC
Power
—
2
+24V DC
Power
—
3
Ground
Ground
—
4
Not connected
Not connected
—
5
In 2
Trigger and hold
See
User Manual
6
In 1
Not used
Not used
7
Out 2
Light array interrupted
0V DC = interrupted
24V DC = not interrupted
8
Out 1
Overhang
24V DC = no overhang
Or over-height (special function)
Pin
2 Wire
4 Wire
1
0 VDC
0 VDC
2
-
Rx+
3
Shielding
Shielding
4
-
Rx-
5
B
Tx+
6
A
Tx-
PNP
D7 LED - Power
RS485
Extension
PCB
D3 LED Out 1
D4 LED Out 2
D9 Error
D8 Com Tx
D6 LED In 2
D5 LED In 1
RJ45 Connector
Emitter
RJ45 Connector
Receiver
D2 LED
D1 LED
Pot 2
Pot 1
Removable
Spring-Loaded
Connector
S1
J2
J12
J13
S2
Out 1
Out 2
In 1
In 2
n. c.
Earth.
24 VDC
0 VDC
In 2
PNP
NPN
PNP
NPN
In 1
Input
Logic
Jumpers
In 2
PNP
NPN
PNP
NPN
In 1
Input
Logic
Jumpers
The following figure provides additional information on the
impedances associated with each of the RS485 inputs.
Figure 7: Input Schematic of the RS485 Terminal
LED Indicators
The following table describes LED D8 and D9 on the RS485
extension PCB.
Table 19: RS485 Controller LED Status
LED
Description
Color
Meaning
D8
Data communication
Off
No communication
Green flashing
Communication active
D9
RS485 Error
Off
No RS485 error
Red
RS485 error