7.6.3 Electrical
Connections
Terminal
Function
Connector
Terminal
Function
Connector
11 Out
41
In
–
12
Out +
42
In +
input
channel 1
13
43
In
–
14
Ex output
channel 1
44 In
+
input
channel 2
21 Out
51
GND
22
Out +
52
+24 V DC
power supply
23
53 NC
24
Ex output
channel 2
54 COM
status relay
Table 7-12: Electrical Connections
7.6.4 Specifications
Features
HART-compatible for 0.5...2.5 kHz
Configuration and monitoring via FDT/DTM-Software "WI-Manager".
The device can be mounted in the safe area and in Zone 2 / Division 2 and receive signals from Zone 0, 1,
2, 20, 21 and 22, as well as Class I/II/III, Division 1, Group A-G.
The mA current signal inputs are completely electrically isolated.
The device detects automatically whether an active or passive current signal is connected.
Extended self diagnostic: Monitoring of error events (e.g. cable breakage) via status relay.
Front LEDs indicates operation status and malfunction.
3-way galvanic isolation between input, output and power supply.