Current limit
≤ 28 mA
Effect of supply voltage change
<
10 μA
2-wire 4…20 mA Current Loop Output
Signal range
3.5...23 mA
Load resistance
≤ (V
supply
– 3.5 V) / 0.023 A [Ω]
Load stability
≤ 0.01 % of span/100 Ω
External 2-wire supply voltage
3.5…26 V DC
Effect of external 2-wire supply voltage change
< 0.005 % of span / V
Accuracy
Absolute Accuracy
Temperature Coefficient
General values
≤
0.1 % of span
≤
0.01 % of span / °C
Basic values
≤
16 µA
≤
1.6 µA / °C
Status Relay
Safe Area
Zone 2 Installation
Voltage max.
125 V AC / 110 V
32 V AC / 32 V DC
Current max.
0.5 A AC / 0.3 A
0.5 A AC / 1 A DC
Power max.
62.5 VA / 32 W
16 VA / 32 W
Power Supply
Supply voltage
19.2…31.2 V DC
Max. consumption (2-channels)
≤ 3 W
Fuse
1.25 A / 250 V AC
Isolation Voltages (reinforced insulation), Test/Operation
Inputs / outputs / supply
2.6 kV AC / 300 V AC
Output 1 to output 2
1.5 kV AC / 150 V AC
Status relay to supply
1.5 kV AC / 150 V AC
Environmental Specifications
Specifications range
-20…+60 °C
Storage temperature
-20…+85 °C
Relative humidity (non-condensation)
< 95 %
Calibration temperature
+20…28 °C