Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver)
1066540000/01/12.11
179
14
13
12
11
24
23
22
21
54
53
52
51
44
43
42
41
CH1
CH2
Configuration
CBX200 for
-20
Ta
+60ºC
≤
≤
in ha
zardous area
Not connected
in ha
zardous area
Not connected
mA
mA
+
-
+
-
ACT20X-(2)SAI-(2)HAO-S
Hazardous Classified Location
Class I / II / III, Division 1, Group A,B,C,D,E,F,G
Class I, Zone 0 / 1 / 2, Group IIC, IIB, IIA or
Zone 20 / 21
Unclassified Location or
Hazardous Classified Location
Class I, Division 2, Group A,B,C,D T4
Class I, Zone 2, Group IIC, IIB, IIA T4
Simple apparatus or
intrinsic safe apparatus
with entity parameters:
Vmax (Ui)
≥ Vt (Uo)
Imax (Ii)
≥ It (Io)
Pi
≥ Pt (Po)
Ca
≥ Ccable + Ci
La
≥ Lcable + Li
Illustration 7-56:
FM Installation Drawing
Terminal CH1 (11, 12), CH2 (21, 22)
Ex Output
U
o
28
V
I
o
93
mA
P
o
0.65
W
Group
C
o
L
o
IIC 0.08
F 4
mH
IIB 0.65
F 16
mH
IIA 2.15
F 32
mH
- ACT20X-HDI-SDO: NAMUR pulse isolator (2 pages)
- ACT20X-SDI-HDO: Solenoid/Alarm driver (2 pages)
- G108 Ultra SlimPak (4 pages)
- G118 Ultra SlimPak (4 pages)
- G128 Ultra SlimPak (4 pages)
- G168 Ultra SlimPak (4 pages)
- G408 Ultra SlimPak (4 pages)
- G408-1000 Ultra SlimPak (4 pages)
- G418 Ultra SlimPak (4 pages)
- G428 Ultra SlimPak (4 pages)
- G438 Ultra SlimPak (4 pages)
- G448 Ultra SlimPak (4 pages)
- G468 Ultra SlimPak (4 pages)
- G478 Ultra SlimPak (4 pages)
- HS01 Heat Sink (Ultra SlimPak series) (2 pages)
- WAVE Analog 2 OLP (7 pages)
- WAVE Analog DC/DC (7 pages)
- WAVE Analog DC Alarm (10 pages)
- WAVE Analog OLP (7 pages)
- WAVE Analog PRO Bridge (9 pages)
- WAVE Analog PRO DC (15 pages)
- WAVE Analog PRO Frequency (15 pages)
- WAVE Analog PRO RTD (13 pages)
- WAVE Analog PRO Thermo (13 pages)
- DC/DC CCC DC - with voltage supply on both sides (8 pages)
- DC/DC CCC HF - with 3 way separation (5 pages)
- DC/DC CCC LP - with voltage supply on the output side (8 pages)
- DC/DC CCC LP - without additional voltage supply (8 pages)
- PT 100/2 sig conditioners for current output (14 pages)
- PT 100/2 sig conditioners for voltage output (12 pages)
- PT 100/4 signal conditioners for current output (18 pages)
- PT 100/4 signal conditioners for voltage output (14 pages)
- Thermo Signal Conditioners for current & voltage output (14 pages)
- WAVE Control: Current Monitoring Module (6 pages)
- WAVE Control: VMA Vac Voltage-Monitoring Module (9 pages)
- ITX+ - Universal signal isolator / amplifier (64 pages)
- PMX400TMP - Display instrument for control panel (39 pages)
- PMX420SERIES - Display instrument for control panel (68 pages)
- Portacal 1000 - Instrument Calibrator (41 pages)
- Portacal 275 - Signal source and loop calibrator (32 pages)
- PTX800D - Scalable pulse and frequency counter (22 pages)
- wavePak - Configurable singal isolator-converter (28 pages)
- PU-Overvoltage in Mains Control (4 pages)
- IE-MC-VL Series - Industrial Ethernet Media Converters (14 pages)