40 USG Exterior Ceiling Applications

USG Drywall Suspension System

NOA No. 12-0924.03

75 psf uplift, for High Velocity Hurricane Zones

System Components

Main Runners

DGLW26

Main Runner Splice

DGSC-180, attached to main runner on each side with two no. 8, S12 screws.

(in required)

Hanger wire and compression post located within 69 of splice.

Cross Tee

DGLW 224

Perimeter Channel

DGCM2, fastened to structure with #8 screws (or equivalent) at 89 OC

Molding

Compression Posts

Size and gauge to be determined by a qualified structural engineer depending on project conditions, such as

plenum height and supporting structure type.

Sheathing panels

One layer Securock Glass Mat sheathing panels, 1/29 or 5/89 thick, installed with long dimensions parallel

with main runners, attached to main runners and cross tees with #8, 1-1/49 truss head screws spaced 89 OC,
end joints staggered.

Direct Applied

Fiberglass reinforcing mesh imbedded with acrylic modified cementitious basecoat, acrylic finish.

Exterio

r

Finish System

(by others)

For complete installation details, see Miami-Dade County Notice of Acceptance no. 12-0924.3