beautypg.com

Systems overview, Performance selector – USG Exterior Ceiling Applications Systems Guide User Manual

Page 4

background image

3 USG Exterior Ceiling Applications

Main Tee /
Carrier System

Spacing

Uplift Class

Test Standard

Maximum
Load Rating¹
(w)

Equivalent
Wind Speed²
(v)

Main Tee

Cross Tee

Compression
Post

P

araline

II Linear Metal

Ceiling System

Symmetrical
Carrier

48 in

N/A

24 in

N/A

UL1897

46 psf

134 mph

24 in

N/A

24 in

Class 90

UL580

90 psf

188 mph

P

araline

Plus Linear

Metal Ceiling System

Paralock Carrier

48 in

24 in

24 in

Class 30

UL580

30 psf

108 mph

48 in

24 in

24 in

N/A

UL1897

55 psf

147 mph

24 in

24 in

30 in

Class 60

UL580

60 psf

153 mph

24 in

24 in

24 in

Class 90

UL580

90 psf

188 mph

24 in

24 in

24 in

N/A

UL1897

102 psf

200 mph

F

ineline

DXFEV with

C

elebration

Metal

Ceiling Panels

DXFEVH 2924

48 in

24 in

24 in

Class 30

UL580

30 psf

108 mph

24 in

48 in

48 in

Class 30³

Engineering
Analysis

30 psf

108 mph

24 in

24 in

24 in

Class 90

UL580

90 psf

188 mph

24 in

24 in

24 in

N/A

UL1897

102 psf

200 mph

DXFEVH 2930

30 in

30 in

30 in

N/A

UL1897

68 psf

163 mph

30 in

30 in

30 in

Class 60

UL580

60 psf

153 mph

ZXLA with s

heetroCk

Lay-in Ceiling Panel
C

lima

P

lus

ZXLA26

48 in

24 in

24 in

N/A

UL1897

26 psf

101 mph

24 in

48 in

24 in

Class 30

UL580

30 psf

108 mph

24 in

48 in

24 in

N/A

UL1897

85 psf

182 mph

48 in

24 in

24 in

N/A

UL1897

21 psf

91 mph

USG Drywall Suspension
System

DGLW26

48 in

24 in

24 in

Class 15

UL580

15 psf

77 mph

48 in

16 in

30 in

Class 15

UL580

15 psf

77 mph

48 in

24 in

30 in

Class 15

UL580

15 psf

77 mph

24 in

24 in

30 in

Class 30

UL580

30 psf

108 mph

24 in

24 in

42 in

Class 60

UL580

30 psf

108 mph

24 in

24 in

30 in

Class 90

UL580

90 psf

188 mph

24 in

16 in

24 in

Class 90

UL580

90 psf

188 mph

24 in

16 in

24 in

N/A

Miami Dade
TAS202&203

75 psf

171 mph

¹ Ultimate loads per UL 1897 are 15% greater than the values presented. The values presented for UL 1897 have a 0.85 coefficient

applied to account for possible installation deficiencies.

2 Calculated using simplified formula on page four.
3 Value derived through engineering calculation

Systems Overview

Performance Selector

An example of P

ixels

frame-mounted backlit installation with GE Tetra

®

PowerGrid is on display

at GE Lighting & Electrical Institute at historic Nela Park, Cleveland, OH (photo above)