beautypg.com

Usg drywall suspension system, Wind uplift resistance for exterior soffitts – USG Exterior Ceiling Applications Systems Guide User Manual

Page 34

background image

33 USG Exterior Ceiling Applications

Wind Uplift Resistance for Exterior Soffitts

USG Drywall Suspension System

compression

post

cross tee

main tee

C

D

B

A

hanger wire

Component Spacing
Max Spacing (in.)

Test
Record

UL
Class

Max
Uplift Load
(PSF)

Equivalent
Wind Speed,
(MPH)

(A)
Main
Runner

(B)
Cross Tee

(C)
12 Gauge
Hanger Wire

(D)
Compression
Post

Exterior soffit
Panels

Plenum
Height¹
(in)

Max
compression
post load (lbs)

Test
Standard

UL526
page 36

15

15

77

48

24

24

24

Single layer 5/89
gypsum panels

141

183.2

UL 580

UL526A, B
page 37

15

15

77

48

16 (526A)
24 (526B)

48

30

single layer 1/29
gypsum panels

128

229

UL 580

UL526C
page 38

30

30

108

24

24

48

30

single layer 1/29
gypsum panels

130

225

UL 580

UL526D
page 39

60

60

188

24

24

48

42

double layer 5/89
gypsum panels

76

525

UL 580

UL526E
page 40

90

90

188

24

24

48

30

double layer 5/89
gypsum panels

76

525

UL 580

UL526F
page 41

90

90

188

24

16

48

24

Single layer 5/89
gypsum panels,
single layer 3/89
plywood

76

525

UL 580

NOA No. 12-
0924.03
page 42

N/A

+75, -75

171

24

16

24

24

single layer 1/29
or 5/89 glass mat
sheathing w/ direct
applied EFIS

24

300

TAS 202,
TAS 203

1 Larger plenum heights require compression post size and gauge to be determined by a quaified structural engineer.