Usg drywall suspension system, Wind uplift resistance for exterior soffitts – USG Exterior Ceiling Applications Systems Guide User Manual
Page 34
33 USG Exterior Ceiling Applications
Wind Uplift Resistance for Exterior Soffitts
USG Drywall Suspension System
compression
post
cross tee
main tee
C
D
B
A
hanger wire
Component Spacing
Max Spacing (in.)
Test
Record
UL
Class
Max
Uplift Load
(PSF)
Equivalent
Wind Speed,
(MPH)
(A)
Main
Runner
(B)
Cross Tee
(C)
12 Gauge
Hanger Wire
(D)
Compression
Post
Exterior soffit
Panels
Plenum
Height¹
(in)
Max
compression
post load (lbs)
Test
Standard
UL526
page 36
15
15
77
48
24
24
24
Single layer 5/89
gypsum panels
141
183.2
UL 580
UL526A, B
page 37
15
15
77
48
16 (526A)
24 (526B)
48
30
single layer 1/29
gypsum panels
128
229
UL 580
UL526C
page 38
30
30
108
24
24
48
30
single layer 1/29
gypsum panels
130
225
UL 580
UL526D
page 39
60
60
188
24
24
48
42
double layer 5/89
gypsum panels
76
525
UL 580
UL526E
page 40
90
90
188
24
24
48
30
double layer 5/89
gypsum panels
76
525
UL 580
UL526F
page 41
90
90
188
24
16
48
24
Single layer 5/89
gypsum panels,
single layer 3/89
plywood
76
525
UL 580
NOA No. 12-
0924.03
page 42
N/A
+75, -75
171
24
16
24
24
single layer 1/29
or 5/89 glass mat
sheathing w/ direct
applied EFIS
24
300
TAS 202,
TAS 203
1 Larger plenum heights require compression post size and gauge to be determined by a quaified structural engineer.