Installation, Wall switch, Optional wall thermostat – Regency Horizon HZ42STE Medium Gas Fireplace User Manual
Page 36: Optional remote control, Gt/gtm remote features
36
Regency Horizon™ HZ42STE Gas Fireplace
INSTALLATION
WALL SWITCH
(Included with Unit)
1) Run the supplied 10' of wire through the right
or left side gas inlet opening. Be careful not to
damage wire.
Note: We recommend a maximum of 10' of wire
but if you wish to go with a longer run,
use the Thermostat Wire Table.
2) Connect the wire to the wall switch and install
into the receptacle box). Also attach wires to
the valve as shown below.
Optional
WALL THERMOSTAT
A wall thermostat may be installed if desired, connect
the wires as per the wiring diagram. Use table below
to determine the maximum wire length.
Note: Preferable if the thermostat is installed
on an interior wall.
Regency
®
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or UL
approved may be used.
Optional
REMOTE CONTROL
Use the Regency
®
Remote Control Kit approved
for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
1) Choose a convenient location on the wall to install
the receiver and the receptacle box (protection
from extreme heat is very important). Run wires
from the fi replace to that location. Use Thermo-
stat Wire Table.
2) See optional remote control instruction manual
for detailed instructions.
GT/GTM REMOTE FEATURES
**GTMF NOT OFFERED ON THE HZ42 ST
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
584 Proflame GT Series
Feature Sheet
(X)
Indicates Included Feature
Note 1 ~ Profl ame Flame Modulator for GTM & GTMF Remote Controls are sold seperately. Choice of NG or
LP fl ame modulator (to match unit fuel type). See Regency Retail Price pages for complete details
1
1
1
Note: Regency Profl ame systems include a white and black wall cover & switch.
**
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.