beautypg.com

Installation, Vent restrictor position – Regency Horizon HZ42STE Medium Gas Fireplace User Manual

Page 15

background image

Regency Horizon™ HZ42STE Gas Fireplace

15

INSTALLATION

Vent restriction is required for certain venting installations, see the diagrams in the "Venting
Arrangements" section to determine if they are required for your installation.

The Vent Restrictor plate is located on the inside top of the fi rebox.

To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;

1) Remove the glass door.

2) Remove the screws that hold the vent restrictor plate in place.

3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.

4) Once the vent restrictor plate is in the required position, secure with screws.

VENT RESTRICTOR POSITION

3/4”

1-1/4”

2-1/2”

3”

SET 0

FACTORY SET

THIS HOLE SETS THE

VENT RESTRICTOR

AT 3”

SET 1

THIS HOLE SETS THE

VENT RESTRICTOR

AT 2-1/2”

SET 2

THIS HOLE SETS THE

VENT RESTRICTOR

AT 1-1/4”

SET 3

THIS HOLE SETS THE

VENT RESTRICTOR

AT 3/4”