Regency Horizon™ HZ42STE Gas Fireplace

31

INSTALLATION

HIGH ELEVATION

This unit is approved for altitude 0 to 4500 ft.
(CAN1 2.17-M91).

GAS LINE

INSTALLATION

Since some municipalities have additional local
codes it is always best to consult with your local
authorities and the CAN/CGA B149 installation
code.

For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.

When using copper or fl ex connectors use only
approved fi ttings. Always provide a union so that
gas lines can be easily disconnected for servicing.
Flare nuts for copper lines and fl ex connectors
are usually considered to meet this requirement.

NOTE: A shutoff / dante valve should be sup-
plied in or near the unit (or as per local codes)
for ease of servicing this appliance.

IMPORTANT: Always check for gas leaks with
a soap and water solution or gas leak detector.
Do not use open fl ame for leak testing.

HZ42STE-NG SYSTEM DATA

Min. Supply Pressure

5" WC (1.25 kpa)

Low Setting Man.
Pressure

1.6" WC (0.40kpa)

Max. Manifold
Pressure

3.5" WC (0.87 kpa)

Orifi ce Size

#40 DMS

Minimum Input

17,500 Btu/h
(5.13 kW)

Maximum Input

26,000 Btu/h
(7.62 kW)

HZ42STE LP SYSTEM DATA

Min. Supply Pressure

12" WC (2.98 kpa)

Low Setting Man.
Pressure

6.4" WC (1.59kpa)

Max. Manifold
Pressure

10" WC (2.49 kpa)

Orifi ce Size

#53 DMS

Minimum Input

19,500 Btu/h
(5.71 kW)

Maximum Input

24,500 Btu/h
(7.18 kW)

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.

Minimum Air Shutter Opening:

NG Fully Closed
LP 3/16"

With Logs:
NG 1/4"
LP Full open

Note: Any damage due to carboning resulting

from improperly setting the aeration
controls is NOT covered under warranty.

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut-off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa). Disconnect
piping from valve at pressures over 1/2 psig.

The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.

Note: To properly check gas pressure, both

inlet and manifold pressures should be
checked using the valve pressure ports
on the valve.

1) Make sure the valve is in the "OFF" position.

2) Loosen the "IN" and/or "OUT" pressure tap(s),

turning counterclockwise with a

1/8"

wide

fl at screwdriver.

3) Attach manometer to "IN" and/or "OUT" pressure

tap(s) using a 5/16" ID hose.

4) Light the pilot and turn the valve to "ON" position.

5) The pressure check should be carried out with

the unit burning and the setting should be within
the limits specifi ed on the safety label.

6) When

fi nished reading manometer, turn off the

gas valve, disconnect the hose and tighten the
screw (clockwise) with a 1/8" fl at screwdriver.
Note: Screw should be snug, but do not over
tighten.

Periodically check the pilot fl ames. Correct
fl ame pattern has three strong blue fl ames: 1
fl owing around the thermopile, 1 around the
thermocouple and 1 fl owing across the burner.

Note: If you have an incorrect fl ame pattern,

contact your Regency

®

dealer for further

instructions.

Incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the burner or thermopile
or thermocouple.

PILOT ADJUSTMENT

886 S.I.T. VALVE

DESCRIPTION

1) Manual high/low adjustment
2) Pilot

adjustment

3) Outlet

Pressure

Tap

4) Inlet

Pressure

Tap

5) Pilot Outlet
6) Main Gas Outlet
7) Main Gas Inlet

1

3

2

4

5

6

7

Burner

Flame Sensor

Pilot

Ignitor